Analisis Pengasutan Motor Induksi Menggunakan Softstarter dan Inverter
DOI:
https://doi.org/10.53695/jm.v2i2.603Keywords:
3-phase induction motor, Torque, Starter, Softstarter, Inverter.Abstract
An induction motor that is started directly without using the starting method will draw 5 to 7 times the full load current and will only produce 1.5 to 2.5 times the full load torque. A large current will result in a voltage drop on the line so that it can interfere with other equipment connected to the line. For large-power motors, especially 3-phase induction motors, it will require a large starting current along with a large-power motor, so with motor power above 30 HP and above it is not recommended to start the motor directly without using the starting method. Some of the most commonly used starting methods are Direct on line (DOL), Star-Delta, Auto-transformer, Primary Resistance, Secondary Resistance, Inverter, and SoftStarter. Where the most widely used in the field is the DOL method, but this method still produces a large starting current. If it continues, it will shorten the life of the motor itself. This paper discusses the comparison between starting on softstarter and inverter on starting current. The results of the analysis of the starting current on the softstarter starting is 741A which is achieved in 9 seconds and the maximum torque produced by a 3-phase induction motor is 368.7 Nm. While the starting current on the inverter starting is 735A which is achieved in 13 seconds and the maximum torque produced by the 3-phase induction motor is 479.5 NmDownloads
References
Zulfikar, Noorly Evalina, Arfis A., “Penggunaan Inverter 3G3MX2 Untuk Merubah Kecepatan Putar Motor Induksi 3 Phasa”,Universitas Muhammadiyah sumatera utara,2019.
Zulfikar, Noorly Evalina, Abdul Azis H, Yoga Tri Nugraha, “Analisis Perubahan Kecepatan Motor Induksi 3 Phasa Dengan Menggunakan Inverter 3g3mx2”, Universitas Muhammadiyah sumatera utara,2019.
Indra Roza,Faisal Irsan Pasaribu,Ahmad Yanie,Agus Almi,Thomson Samuel Sinaga, “Analisa Pengaruh Penggunaan VSD ( Variable Speed Drive) Pada Konsumsi Energi Di Pt. Lestari Alam Segar” . 2021.
Partaonan Harahap ST,MT . “Harmonisa Pada Rangkaian Inverter Satu Fasa” . 2018.
Wiratman “Analisis Perbandingan Pengasutan Pada Arus Start Dengan Menggunakan Softstarter Dan Inverter Pada Motor Induksi 3 Fasa”. 2016.
Koes Indrakoesoema,Yayan Andrianto, Kiswanto, ” Pengaruh Softstarter Pada Arus Motor Pompa Pendingin Primer Rsg-Gas”, Pusat Reaktor Serba Guna – Batan, Puspiptek Serpong, Tangerang Selatan, 15310.
Asnil,Krismadinata,Irma Husnaini,”Inverter tiga fasa Untuk Pembangkit Listrik Tenaga Surya’’,Teknik Elektro Universitas Negeri Padang,2019.
Yulis Septarangga,”Inverter Dengan Tegangan 12V DC Dan Tegangan Keluaran AC Dengan Frekuensi Yang Dapat Di Atur ”,Fakultas Sains Dan Teknologi Sanata Dharma,2019.
Ardhan Izatur Rachman, “Analisis Model Pengasutan Motor Induksi 3 Fasa Terhadap Arus Start Dan Torsi” ,Fakultas Teknik Univesitas Nusantara,2020.
Lalu Riza Aliyan . “Desain Inverter Tiga Fasa Dengan Minimum Total Harmonic Distortion Menggunakan Metode SPWM” , Jurnal EECCIS Vol. 8 No.1 ,Juni 2014. 11. Ronaldi Hutabalian ,”Desain Dan Analisa Inverter Tiga Fasa Dengan Metode SVPWM Sebagai Penggerak Motor Induksi Tiga Fasa Pada Aplikasi Sepeda Listrik” ,Teknik Elektro Universitas Riau,2016. 12. Satria Yudha “Anali
Downloads
Published
How to Cite
Issue
Section
License
This is an open-access journal. All works published under Creative Commons license CC-BY-SA which mean that all content is freely available at no charge to the user or his/her Institution. User are allowed to read, download, copy, write, improve, and create derivative creation even for other lawful purposes, this license permits anyone to, as long as they cite and license the derivative creation under similar terms
Jurnal Mesil (Mesin Elektro Sipil) is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.